top of page
Idle Free - home page (10).png

Professional A/C Supplier for Trucking & Beyond

Electric Air Conditioner

Electric air conditioners for trucks, construction, agricultural machinery and other specialty vehicles

Split Bunk System
DL-2000FUB
DL-2600FUB
Rated Input Voltage
DC12V
DC24V
Working Voltage Range
DC10.8-15.5V
DC21.5-32V
Rated Cooling Capacity (*)
7500BTU
10000BTU
Rated Input Power (*)
7500BTU
912W
Rated Current Consumption (*)
50A
38A
Current Draw Range
25-70A
10-45A
Air Flow
250CFM
300CFM
Working Refrigerant
R-134a (630g)
R-134a (610g)
Compressor Type
12V Electric Compressor
24V Electric Compressor
Weight (Indoor Unit)
7kg / 15lbs
7kg / 15lbs
Weight (Outdoor Unit)
25kg / 55lbs
25kg / 55lbs
Dimensions (Indoor unit)
534 x 315 x 222 mm
534 x 315 x 222 mm
Dimensions (Outdoor Unit)
682 x 465 x 192 mm
682 x 465 x 192 mm
  • (*) In accordance with JIS standard, test conditions: outside temperature 95°F, return temperature 80.6°F.

  • Being porudct improvement or updates, parameters will be changed without prior notice

  • The AC is designed for T1 climate type (69.8°F to 109.4°F)

Split Wall-Mount
DL-2000F1
DL-2600F
Rated Input Voltage
DC12V
DC24V
Working Voltage Range
DC21.5-32V
DC10.8-15.5V
Rated Cooling Capacity (*)
7500BTU
10000BTU
Rated Input Power (*)
600W
912W
Rated Current Consumption (*)
50A
38A
Current Draw Range
25-70A
10-45A
Air Flow
250CFM
300CFM
Working Refrigerant
R-134a(610±20g)
R-134-a(610±20g)
Compressor Type
12V Electric Compressor
24V Electric Compressor
Weight (Indoor)
10kg / 22lbs
10kg / 22lbs
Weight (Outdoor)
25kg / 55lb
25kg / 55lbs
Dimensions (Indoor)
540 x 362 x 165mm
540 x 362 x 165mm
Dimensions (Outdoor)
682 x 465 x 192mm
682 x 465 x 192mm
  • (*) In accordance with JIS standard, test conditions: outside temperature 95°F, return temperature 80.6°F.

  • Being porudct improvement or updates, parameters will be changed without prior notice

  • The AC is designed for T1 climate type (69.8°F to 109.4°F)

Untitled design - 2024-08-23T095742.288.png
Split Rooftop
DL-2000FT-BY
DL-2600FT-BY
Rated Input Voltage
DC12V
DC24V
Working Voltage Range
DC10.8-15.5V
DC215-32V
Rated Cooling Capacity (*)
7500BTU
10000BTU
Rated Input Power (*)
600W
912W
Rated Current Consumption (*)
50A
38A
Current Draw Range
25-70A
10-45A
Air Flow
250CFM
300CFM
Working Refrigerant
R-134a (610±20g)
R-134a (610±20g)
Compressor Type
12 Electric Compressor
24V Electric Compressor
Weight (Indoor)
10kg / 22lbs
10kg / 22lbs
Weight (Outdoor)
25kg / 55lbs
25kg / 55lbs
Dimensions (Indoor)
540 x 362 x 165mm
540 x 362 x 165mm
Dimensions (Outdoor)
690 x 430 x 194mm
690 x 430 x 194mm
  • (*) In accordance with JIS standard, test conditions: outside temperature 95°F, return temperature 80.6°F.

  • Being porudct improvement or updates, parameters will be changed without prior notice

  • The AC is designed for T1 climate type (69.8°F to 109.4°F)

Untitled design - 2024-08-23T110029.327.png
Lonomotive AC System
DL-5000-DC
DL-5000-AC
Cooling Input Voltage
DC110V
AC380V
Cooling Capcity (*)
5000W
5000W
Cooling Input Power (*)
2090W
2200W
Cooling Current Consumption (*)
19A
3.5A
Heating Input Power (*)
DC110V
AC380V
Heating Capacity (*)
3000W
3000W
Heating Input Power (*)
3000W
3000W
Heating Current Consumption (*)
27.3A
4.7A
Air Flow
589CFM
589CFM
Working Refrigerant
R-410a (1140g)
R-410a (1140g)
Frame Material
SS304
SS304
Weight
74kg / 163lbs
74kg / 163lbs
Dimensions
1180 x 726 x 285mm
1180 x 726 x 285mm
  • (*) In accordance with JIS standard, test conditions: outside temperature 95°F, return temperature 80.6°F.

  • Being porudct improvement or updates, parameters will be changed without prior notice

  • The AC is designed for T1 climate type (69.8°F to 109.4°F)

Untitled design - 2024-08-23T113100.232.png
Rooftop A/C
DL-1200-12V
DL-1500-24V
DL-1800-24V
DL-1500-48V
DL-1800-48V
DL-1800-72V
DL-1800-96V
Rated Input Voltage
DC12V
DC24V
DC24V
DC48V
DC48V
DC72V
DC96V
Rated Cooling Capacity (*)
5500BTU
6500BTU
8500BTU
7000BTU
9000BTU
11000BTU
11000BTU
Rated Power Consumption (*)
660W
790W
940W
790W
940W
1224W
1200W
Air Flow
210CFM
250CFM
300CFM
250CFM
300CFM
300CFM
300CFM
Weight
29kg / 64lbs
29kg / 64lbs
42kg / 93lbs
29kg / 64lbs
42kg / 93lbs
42kg / 93lbs
42kg / 93lbs
Installation Cut Out Size
380 x 260mm
380 x 260mm
360 x 360mm
380 x 260mm
360 x 360mm
360 x 360mm
360 x 360mm
Refrigerant
R-134a (330g)
R-134a (360g)
R-134a (540g)
R-134a (360g)
R-134a (590g)
R-134a (540g)
R-134a (540g)
Dimensions
700 x 580 x 263mm
700 x 580 x 263mm
885 x 710 x 290mm
700 x 580 x 263mm
885 x 710 x 290mm
885 x 710 x 290mm
885 x 710 x 290mm
  • (*) In accordance with JIS standard, test conditions: outside temperature 95°F, return temperature 80.6°F.

  • Being porudct improvement or updates, parameters will be changed without prior notice

  • The AC is designed for T1 climate type (69.8°F to 109.4°F)

Untitled design - 2024-08-23T134604.384.png

Interested to See How Polar Fox Air Conditioner Can Help Your Fleet to Eliminate Idle and Save Money?

bottom of page